Development of an Optimisation Model of Air-Cooled Chiller Maintenance Management to Improve Availability Performance

  • Denis Mandia Dar es Salaam Institute of Technology
  • Fredrick M. Sanga, PhD Dar es Salaam Institute of Technology
Keywords: Air-Cooled Chiller, Maintenance Management, Optimisation Model Availability Performance, Chiller Performance
Share Article:

Abstract

Air-cooled chillers remain important to climate control in many industries. However, ensuring high availability of such systems has remained a big challenge to their operations, especially in developing countries like Tanzania. The maintenance practices currently adopted are mainly reactive, translating to a frequent occurrence of failures that result in shortened equipment life and energy wastage. In this paper, an optimum data-driven model is developed and validated for managing the maintenance of air-cooled chillers to advance the performance of their availability. Quantitative and qualitative data were collected from seven chillers at Julius Nyerere International Airport using a mixed-methods methodology approach at Dar es Salaam, including operations records, performance indicators, and interviews with experts. Multiple regression analysis highlighted preventive maintenance frequency (β = 0.312), compressor performance (β = 0.241), control system reliability (β = 0.225), and energy performance (β = 0.202) as the strongest positive determinants of availability. Contrary to findings in other studies performed under more extreme climates, environmental factors such as ambient temperature and dust had low significance. This can be explained by the stable coastal climate of Dar es Salaam and the relatively controlled infrastructure at JNIA. The model was then validated with an average prediction accuracy of about 98%. This was indicative of its efficiency in predicting the availability of chillers.

Downloads

Download data is not yet available.

References

Algarni, S., Saleel, C. A., & Mujeebu, M. A. (2018). Air-conditioning condensate recovery and applications—Current developments and challenges ahead. Sustainable Cities and Society, 37, 263–274. https://doi.org/10.1016/j.scs.2017.11.032

Barone, G., & Frangopol, D. M. (2014). Life-cycle maintenance of deteriorating structures by multi-objective optimization involving reliability, risk, availability, hazard and cost. Structural Safety, 48, 40–50. https://doi.org/10.1016/j.strusafe.2014.02.002

Catrini, P., La Villetta, M., Kumar, D. M., Morale, M., & Piacentino, A. (2024). Analysis of the operation of air-cooled chillers with variable-speed fans for advanced energy-saving-oriented control strategies. Applied Energy, 367, 123393. https://doi.org/10.1016/j.apenergy.2024.123393

Dos Santos, C. G., Ruivo, J. P., Gasparini, L. B., Rosa, M. T. D. M. G., Odloak, D., & Tvrzská De Gouvêa, M. (2022). Steady-state simulation and optimization of an air cooled chiller. Case Studies in Thermal Engineering, 36, 102142. https://doi.org/10.1016/j.csite.2022.102142

Fong, K. F., & Lee, C. K. (2015). Performance analysis of internal-combustion-engine primed trigeneration systems for use in high-rise office buildings in Hong Kong. Applied Energy, 160, 793–801. https://doi.org/10.1016/j.apenergy.2014.11.059

Gao, Y., Han, H., Ren, Z. X., Gao, J. Q., Jiang, S. X., & Yang, Y. T. (2021). Comprehensive study on sensitive parameters for chiller fault diagnosis. Energy and Buildings, 251, 111318. https://doi.org/10.1016/j.enbuild.2021.111318

Ho, W. T., & Yu, F. W. (2021). Improved model and optimization for the energy performance of chiller system with diverse component staging. Energy, 217, 119376. https://doi.org/10.1016/j.energy.2020.119376

Huang, S., Zuo, W., & Sohn, M. D. (2017). Improved cooling tower control of legacy chiller plants by optimizing the condenser water set point. Building and Environment, 111, 33–46. https://doi.org/10.1016/j.buildenv.2016.10.011

Kabeel, A. E., El-Samadony, Y. A. F., & Khiera, M. H. (2017). Performance evaluation of energy efficient evaporatively air-cooled chiller. Applied Thermal Engineering, 122, 204–213. https://doi.org/10.1016/j.applthermaleng.2017.04.103

Kindole, A., Msambichaka, J., Tekka, R., & Lingwanda, M. (2024). Examination of the Impact of Value Engineering Implementation on the Overall Maintenance Performance of Gravel Roads Maintenance Projects in Tanzania. Journal of Applied Sciences and Environmental Management, 28(7), Article 7. https://doi.org/10.4314/jasem.v28i7.6

Kumar, D. M., Catrini, P., Piacentino, A., & Cirrincione, M. (2023). Advanced modeling and energy-saving-oriented assessment of control strategies for air-cooled chillers in space cooling applications. Energy Conversion and Management, 291, 117258. https://doi.org/10.1016/j.enconman.2023.117258

Lee, P., Lam, P. T. I., Lee, W. L., & Chan, E. H. W. (2016). Analysis of an air-cooled chiller replacement project using a probabilistic approach for energy performance contracts. Applied Energy, 171, 415–428. https://doi.org/10.1016/j.apenergy.2016.03.035

Makahleh, F. M., Badran, A. A., Attar, H., Amer, A., & Al-Maaitah, A. A. (2022). Modeling and Simulation of a Two-Stage Air Cooled Adsorption Chiller with Heat Recovery Part I: Physical and Mathematical Performance Model. Applied Sciences, 12(13), 6542. https://doi.org/10.3390/app12136542

Moghaddas-Zadeh, N., Farzaneh-Gord, M., Ebrahimi-Moghadam, A., & Bahnfleth, W. P. (2023). ANN-based procedure to obtain the optimal design and operation of the compression chiller network – Energy, economic and environmental analysis. Journal of Building Engineering, 72, 106711. https://doi.org/10.1016/j.jobe.2023.106711

Morozyuk, L., Sokolovska-Yefymenko, V., Moshkatiuk, A., Ierin, V., & Basov, A. (2023). Experimental study and analysis of an air-cooled condenser with the fouling on the heat exchange surface for small-scale commercial refrigeration systems. International Journal of Air-Conditioning and Refrigeration, 31(1), 18. https://doi.org/10.1007/s44189-023-00034-8

Olszewski, P. (2022). Experimental analysis of ON/OFF and variable speed drive controlled industrial chiller towards energy efficient operation. Applied Energy, 309, 118440. https://doi.org/10.1016/j.apenergy.2021.118440

Saber, E. M., Tham, K. W., & Leibundgut, H. (2016). A review of high temperature cooling systems in tropical buildings. Building and Environment, 96, 237–249. https://doi.org/10.1016/j.buildenv.2015.11.029

Shirazi, A., Taylor, R. A., Morrison, G. L., & White, S. D. (2017). A comprehensive, multi-objective optimization of solar-powered absorption chiller systems for air-conditioning applications. Energy Conversion and Management, 132, 281–306. https://doi.org/10.1016/j.enconman.2016.11.039

Sun, Y., Xue, H., Wang, W., Wu, S., Wu, Y., Hong, Y., & Deng, S. (2020). Development of an optimal control method of chilled water temperature for constant-speed air-cooled water chiller air conditioning systems. Applied Thermal Engineering, 180, 115802. https://doi.org/10.1016/j.applthermaleng.2020.115802

Torres, Y. D., Calvo, R. R., Herrera, H. H., Guerra, M. A. Á., Sarduy, J. G., & Silva Ortega, J. I. (2021). Procedure to obtain the optimal distribution cooling capacity of an air-condensed chiller plant for a hotel facility conceptual design. Energy Reports, 7, 622–637. https://doi.org/10.1016/j.egyr.2021.07.090

Wu, J., Gagnière, E., Couenne, F., Hamroun, B., Latour, T., & Jallut, C. (2015). A hybrid transient model for simulation of air-cooled refrigeration systems: Description and experimental validation. International Journal of Refrigeration, 53, 142–154. https://doi.org/10.1016/j.ijrefrig.2014.10.008

Yang, H., Rong, L., Liu, X., Liu, L., Fan, M., & Pei, N. (2020). Experimental research on spray evaporative cooling system applied to air-cooled chiller condenser. Energy Reports, 6, 906–913. https://doi.org/10.1016/j.egyr.2020.04.001

Yu, F. W., Ho, W. T., Chan, K. T., & Sit, R. K. Y. (2018). Logistic regression-based optimal control for air-cooled chiller. International Journal of Refrigeration, 85, 200–212. https://doi.org/10.1016/j.ijrefrig.2017.09.026

Zhang, F., Wang, P., & Yi, M. (2021). Design optimization of forced air-cooled lithium-ion battery module based on multi-vents. Journal of Energy Storage, 40, 102781. https://doi.org/10.1016/j.est.2021.102781

Zhao, J., Chen, Z., Li, H., & Liu, D. (2024). A model predictive control for a multi-chiller system in data center considering whole system energy conservation. Energy and Buildings, 324, 114919. https://doi.org/10.1016/j.enbuild.2024.114919

Published
6 February, 2026
How to Cite
Mandia, D., & Sanga, F. (2026). Development of an Optimisation Model of Air-Cooled Chiller Maintenance Management to Improve Availability Performance. East African Journal of Engineering, 9(1), 115-128. https://doi.org/10.37284/eaje.9.1.4471